FM-1
|
Flat bottomed glass 100mL graduated test cylinder starting at 10mL and continuing at 10mL increments
|
FM-3MC
|
Certified Mott metal cylinder gas diffuser
|
FM-3NC
|
Certified Mott metal cylindrical gas diffuser (more uniform air bubbles and greater precision than Norton)
|
FM-4
|
Test assembly includes 1 of each:
FM-1 - 100mL graduated test cylinder
FM-3 - Mott metal cylindrical gas diffuser
FM-10 - glass air-outlet tube
FM-11 - air-inlet tube
FM-12 - sealing washer
FM-13 - two hole rubber stopper
|
FM-5
|
Four position sample storage rack (cylinders not included) |
FM-6
|
Foam Test Tube Support Rack |
FM-7.2
|
Two channel digital indicating Mass Flow Controller, allowing two simultaneous foam tests |
FM-9
|
Automatic-sequencing controller, automatically starts air flow after the 5 minute period of soaking the diffuser, sounds alarm and automatically stops air flow after 5 minutes blowing period, and sounds alarm after 10 minute settling period. Also provided is a digital display time counter showing remaining seconds to the next even requiring operator attention. Available as a stand alone model or incorporated into any of the foam testing baths. |
FM-10
|
Glass air-outlet tube (90º) |
FM-11
|
Chrome plated air-inlet tube |
FM-12
|
Sealing washer (for between inlet tube and diffuser) |
FM-13
|
Rubber stopper (two holes) |
FM-14
|
Air drying tower package with color indicating drying agent, 3" diameter by 12" tall |
FM-15
|
Air supply pump (oil-less diaphragm) |
FM-14/15
|
Air supply assembly mounted on a base with as air supply pump (FM-15) and with an air drying tower (FM-14). Overall dimensions: 9"x10"x14" |
FM-16
|
Mechanically refrigerated bath (12 liters) with a digital indicating controller. Operating temperature range is +10ºC to -35ºC. Designed for pumping cold liquid to cool Model 323 or323-H air foam bath. It allows Model 323 to operated at 24ºC as well as rapidly cool the air chamber to the lower temperature.
Overall dimensions: 14"x23"33" |
FM-16L
|
Flow cooler (used with Model 24 and 28 liquid baths). It is used to maintain the 24ºC bath when the ambient temperature in the laboratory is above 24ºC. |
-17
|
20 liters (5gal.) of Polyalphaolefin (PAO) bath medium oil, containing no silicones. PAO fluid has longer life at higher temperatures then conventional bath medium oils. 27 liters (7 gal.) need to fill each liquid bath. Replaces silicones as heated bath medium. Silicone fluids are not recommended. Even low levels (1 ppm and above) of silicone contamination interfere with test results. |
FM-20
|
For improved consistency of results, two digital indicating mass flow controllers are used for precisely measuring and controlling the amount of air delivered to the air diffuser. The air flow is controlled at either a rate of 94 or 200 ±mL/min. (depending if the testing by ASTM D892 or D6082, respectively). An automated, two channel sequencer automatically starts the air flow after the 5 minutes soak times, after the 6 minutes stops the air flow and sounds an alarm, and again sounds an alarm after the 10 minutes settling period (other times are also available). A touch screen allows the operator selection and full adjustment of all test parameters. All key parameters are displayed during the test. Also displayed is the time remaining to the next event requiring operator attention. |